Indian Journal of Critical Care Medicine
An open access publication of ISCCM™ 
 
Users online: 28 
     Home | Login 
  About Current Issue Archive Search Instructions Online Submission Subscribe Etcetera Contact  
  Navigate Here 
 »   Next article
 »   Previous article
 »   Table of Contents

 Resource Links
 »   Similar in PUBMED
 »  Search Pubmed for
 »  Search in Google Scholar for
 »Related articles
 »   Citation Manager
 »   Access Statistics
 »   Reader Comments
 »   Email Alert *
 »   Add to My List *
 * Requires registration (Free)
 

 Article Access Statistics
    Viewed9460    
    Printed188    
    Emailed3    
    PDF Downloaded861    
    Comments [Add]    
    Cited by others 8    

Recommend this journal

 

 REVIEW ARTICLE
Year : 2008  |  Volume : 12  |  Issue : 1  |  Page : 10--14

Optimal positioning of right-sided internal jugular venous catheters: Comparison of intra-atrial electrocardiography versus Peres' formula


Department of Anesthesia and Critical Care, GR Doshi and KM Mehta Institute of Kidney Diseases and Research Centre, Dr. HL Trivedi Institute of Transplantation Sciences, Civil Hospital campus, Asarwa, Ahmedabad - 380 016, Gujarat, India

Correspondence Address:
Anish M Joshi
49/B 'NAYANRAMYA', Chaitanyanagar, Nr. Stadium Petrol Pump, Stadium Road, P.O. Navjivan, Ahmedabad - 380 014, Gujarat
India
Login to access the Email id


DOI: 10.4103/0972-5229.40943

PMID: 19826584

Get Permissions

Central venous catheters are routinely placed in patients undergoing major surgeries where expected volume and hemodynamic disturbances are likely consequences. The incorrect positioning may give false central venous pressure (CVP) readings leading to incorrect volume replacement and other serious complications. 50 American Society of Anaesthesiologists grade II-IV patients aged 18-60 years were selected for right-sided internal jugular vein (IJV) catheterization using Seldinger's technique. In group A, central venous catheterization was done under electrocardiography (ECG) guidance. In group B, the catheter was inserted blindly using Peres' formula of "height (in cm)/10". The position of the tip of central venous catheter was confirmed radiologically by postoperative chest X-ray. 92% of patients in group A had radiologically correct positioning of catheter tip i.e. above the carina, while in group B 48% patients had over-insertion of the catheter in to the right atrium. Intra-atrial ECG technique to judge correct tip positioning is simple and economical. It can determine the exact position intraoperatively and can justify a delayed postoperative chest X-ray to confirm CVC line tip placement.






[FULL TEXT] [PDF]*


        
Print this article     Email this article

Online since 7th April '04
Published by Medknow