Advertisment Mero
Indian Journal of Critical Care Medicine
An open access publication of ISCCM™ 
 
Users online: 656 
     Home | Login 
  About Current Issue Archive Search Instructions Online Submission Subscribe Etcetera Contact  
  Navigate Here 
 »   Next article
 »   Previous article
 »   Table of Contents

 Resource Links
 »   Similar in PUBMED
 »  Search Pubmed for
 »  Search in Google Scholar for
 »Related articles
 »   Citation Manager
 »   Access Statistics
 »   Reader Comments
 »   Email Alert *
 »   Add to My List *
 * Requires registration (Free)
 

 Article Access Statistics
    Viewed639    
    Printed8    
    Emailed0    
    PDF Downloaded133    
    Comments [Add]    

Recommend this journal

 

 RESEARCH ARTICLE
Year : 2017  |  Volume : 21  |  Issue : 5  |  Page : 257--261

Reliability of ultrasonography in confirming endotracheal tube placement in an emergency setting


1 Department of Emergency Medicine, Jubilee Mission Medical College and Research Institute, Thrissur, Kerala, India
2 Department of Anesthesia and Critical Care, Jubilee Mission Medical College and Research Institute, Thrissur, Kerala, India

Correspondence Address:
Cherish Paul
Department of Anaesthesia and Critical Care, Jubilee Mission Medical College and Research Institute, Thrissur, Kerala
India
Login to access the Email id

Source of Support: None, Conflict of Interest: None


DOI: 10.4103/ijccm.IJCCM_417_16

Rights and Permissions

Background and Objectives: Over the past few years, ultrasonography is increasingly being used to confirm the correct placement of endotracheal tube (ETT). In our study, we aimed to compare it with the traditional clinical methods and the gold standard quantitative waveform capnography. Two primary outcomes were measured in our study. First was the sensitivity and specificity of ultrasonography against the other two methods to confirm endotracheal intubation. The second primary outcome assessed was the time taken for each method to confirm tube placement in an emergency setting. Methods: This is a single-centered, prospective cohort study conducted in an emergency department of a tertiary care hospital. We included 100 patients with indication of emergency intubation by convenient sampling. The intubation was performed as per standard hospital protocol. As part of the study protocol, ultrasonography was used to identify ETT placement simultaneously with the intubation procedure along with quantitative waveform capnography (end-tidal carbon dioxide) and clinical methods. Confirmation of tube placement and time taken for the same were noted by three separate health-care staffs. Results and Discussion: Out of the 100 intubation attempts, five (5%) had esophageal intubations. The sensitivity and specificity of diagnosis using ultrasonography were 97.89% and 100%, respectively. This was statistically comparable with the other two modalities. The time taken to confirm tube placement with ultrasonography was 8.27 ± 1.54 s compared to waveform capnography and clinical methods which were 18.06 ± 2.58 and 20.72 ± 3.21 s, respectively. The time taken by ultrasonography was significantly less. Conclusions: Ultrasonography confirmed tube placement with comparable sensitivity and specificity to quantitative waveform capnography and clinical methods. But then, it yielded results considerably faster than the other two modalities.






[FULL TEXT] [PDF]*


        
Print this article     Email this article

Online since 7th April '04
Published by Wolters Kluwer - Medknow