IJCCM
 

RESEARCH ARTICLE
[View FULLTEXT] [Download PDF
 
Year : 2018  |  Volume : 22  |  Issue : 1  |  Page : 1-4  

Effect of continuous versus intermittent subglottic suctioning on tracheal mucosa by the mallinckrodt taperguard evac oral tracheal tube in intensive care unit ventilated patients: A prospective randomized study

Philippe Seguin1, Harmonie Perrichet1, Estelle Le Pabic2, Yoann Launey1, Marie Tiercin3, Romain Corre3, Graziella Brinchault3, Bruno Laviolle2 
1 Department of Critical Care Medicine, CHU de Rennes and Université Rennes 1, Rennes Cedex 9, France
2 Center of Clinical Investigation, CHU de Rennes and Université Rennes 1, Rennes Cedex 9, France
3 Department of Pulmonary Medecine, CHU de Rennes and Université Rennes 1, Rennes Cedex 9, France

Correspondence Address:
Prof. Philippe Seguin
Hôpital Pontchaillou, Service D'Anesthésie-Réanimation 1, Réanimation Chirurgicale, 2 Rue Henri Le Guilloux, Rennes 35033 Cedex 9
France

Background and Aims: A risk of tracheal mucosa injury induced by subglottic suctioning has been raised. Therefore, this prospective randomized study aims to compare the effect of continuous suctioning of subglottic secretions versus intermittent suctioning of subglottic secretions (CSSS vs. ISSS) secretions on tracheal mucosa in front of the suctioning port of the endotracheal tube. Patients and Methods: Patients requiring intubation or reintubation in Intensive Care Unit with an expected ventilation duration > 24 h were eligible. Participants received CSSS at −20 mmHg or ISSS at −100 mmHg during 15 s and no suction during 8 s. The effect on tracheal mucosa in front of the suction port was assessed after intubation (T0) and before extubation (T1) using bronchoscopy. Tracheal mucosa damages were graded into five categories (no injury, erythema, edema, ulceration, or necrosis). The occurrence (no injury observed at T0 but present at T1) or the worsening (injury observed at T0 exacerbating at T1) was studied. Results: Seventy-three patients were included and 53 patients (CSSS, n = 26 and ISSS, n = 27) were evaluable on the primary endpoint. The occurrence or worsening of tracheal mucosal damages did not differ between the two groups (CSSS, n = 7 [27%] vs. ISSS, n = 5 [17%], P = 0.465). Daily average volume of suctioned secretion was higher with ISSS (74 ± 100 ml vs. 20 ± 25 ml, P < 0.001). Impossibility to aspirate was higher with CSSS (0.14 ± 0.16 per day vs. 0.03 ± 0.07 per day, P < 0.001). Conclusions: Our results suggest that tracheal mucosal damages did not differ between CSSS and ISSS. The aspirated volume was higher and impossibility to aspirate was lower with ISSS. Clinical Trial Registration: ClinicalTrials.gov Identifier: NCT01555229.


How to cite this article:
Seguin P, Perrichet H, Pabic EL, Launey Y, Tiercin M, Corre R, Brinchault G, Laviolle B. Effect of continuous versus intermittent subglottic suctioning on tracheal mucosa by the mallinckrodt taperguard evac oral tracheal tube in intensive care unit ventilated patients: A prospective randomized study.Indian J Crit Care Med 2018;22:1-4


How to cite this URL:
Seguin P, Perrichet H, Pabic EL, Launey Y, Tiercin M, Corre R, Brinchault G, Laviolle B. Effect of continuous versus intermittent subglottic suctioning on tracheal mucosa by the mallinckrodt taperguard evac oral tracheal tube in intensive care unit ventilated patients: A prospective randomized study. Indian J Crit Care Med [serial online] 2018 [cited 2018 Nov 17 ];22:1-4
Available from: http://www.ijccm.org/article.asp?issn=0972-5229;year=2018;volume=22;issue=1;spage=1;epage=4;aulast=Seguin;type=0