Indian Journal of Critical Care Medicine

Register      Login

SEARCH WITHIN CONTENT

FIND ARTICLE

Volume / Issue

Online First

Archive
Related articles

VOLUME 13 , ISSUE 4 ( December, 2009 ) > List of Articles

RESEARCH ARTICLE

Role of noninvasive ventilation in weaning from mechanical ventilation in patients of chronic obstructive pulmonary disease: An Indian experience

Shiva B. N. Prasad, Rajan Khanna

Keywords : Chronic obstructive pulmonary disease, mechanical ventilation, noninvasive ventilation, respiratory failure, weaning

Citation Information : Prasad SB, Khanna R. Role of noninvasive ventilation in weaning from mechanical ventilation in patients of chronic obstructive pulmonary disease: An Indian experience. Indian J Crit Care Med 2009; 13 (4):207-212.

DOI: 10.4103/0972-5229.60173

License: CC BY-ND 3.0

Published Online: 01-10-2012

Copyright Statement:  Copyright © 2009; The Author(s).


Abstract

Background: Endotracheal intubation and mechanical ventilation (MV) are often needed in patients of chronic obstructive pulmonary disease (COPD) with acute hypercapnic respiratory failure. The rate of weaning failure is high and prolonged MV increases intubation associated complications. Objective: To evaluate the role of Noninvasive ventilation (NIV) in weaning patients of chronic obstructive pulmonary disease (COPD) from MV, after T piece trial failure. Design: A prospective, randomized, controlled study was conducted in a tertiary care centre. 30 patients of acute exacerbation of COPD with acute on chronic hypercapnic respiratory failure, who were mechanically ventilated, were included in the study A T-piece weaning trial was attempted once the patients achieved satisfactory clinical and biochemical parameters. After T-piece failure, defined as pH < 7.35, PaCO 2 >50 mmHg, PaO 2 < 50 mmHg, HR >100/min, RR >35, patients were randomized to receive either NIV or PSV. Results: Demography, severity of disease and clinical profiles were similar in both groups. No significant difference between the two groups in duration of MV (6.20 ± 5.20 days vs. 7.47 ± 6.38 days, P > 0.05), duration of weaning (35.17 ± 16.98 and 47.05 ± 20.98 hours, P > 0.05) or duration of ICU stay (8.47 ± 4.79 and 10.80 ± 5.28 days, P > 0.05) in Gp I and Gp II, respectively. Five patients developed VAP in the PSV group, where as only one patient had pneumonia in the NIV group. Lesser number of deaths in the NIV group at discharge from ICU (3 vs. 5 patients, respectively) and at 30 days (5 vs. 9 patients, respectively), it did not achieve statistical significance (P > 0.05). Conclusion: NIV is as useful as PSV in weaning and can be better in weaning failure especially in COPD for earlier weaning, decrease ICU stay, complications and mortality.


PDF Share
  1. Weaning mechanical ventilatory support. In: Macintyre NR, Brasnon RD, editors. Mechnical ventilation. Philadelphia: Saunders; 2001. p. 348-57.
  2. Complications associated with mechanical ventilation. In: Tobin MJ, editor. Principles and practice of mechanical ventilation. New York: McGraw Hill; 1994. p. 775-92
  3. A comparison of four methods of weaning from mechanical ventilation. N Engl J Med 1995;332:345-50.
  4. Comparison of these methods of gradual withdrawl from ventilatory support during weaning from mechanical ventilation. Am J Respir Crit Care Med 1994;150:896-903.
  5. Noninvasive ventilation in acute exacerbation of COPD. In: Simmonds AK, editor. Noninvasive respiratory support. 2nd ed. London: Arnold; 2001. p. 30-46.
  6. Noninvasive mechanical ventilation in the weaning of patients with respiratory failure due to COPD. Ann Intern Med 1998;128:721-8.
  7. Noninvasive pressure support ventilation in COPD with post extubation hypercapnic respiratory insufficiency. Eur Respir J 1998;11:1349-53.
  8. Noninvasive ventilation as a systemic exacerbation and weaning technique in acute on chronic respiratory failure. Am J Respir Crit Care Med 1999;160:86-92.
  9. Non-invasive ventilation during persistent weaning failure. Am J Resp Crit Care Med 2003;168:70-6.
  10. NIV for acute exacerbation of COPD. N Engl J Med 1995;333:813-22.
  11. Pulmonary function laboratory in the tropics: Needs, problems and solutions. In: Sharma OP, editor. Lung disease in the tropics. New York: Marcel Dekker; 1991. p. 523-42.
  12. Reversal of acute exacerbations of COPD in inspiratory assistance and a face mask. N Engl J Med 1990;91:865-70.
  13. Respiratory pump failure. In: Fishman AP, Elias JA, Fishman JA, Grippi MA, Kaiser LR, Senior RM, editors. Fishman′s pulmonary diseases and disorders. 3rd ed, Vol 2. New York: McGrawHill; 1997. p. 2605-27.
  14. Weaning from mechanical ventilation. In: Essentials of mechanical ventilation. New York: McGraw Hill; 1996. p. 77-83.
  15. The physiologic determinants of ventricular dependence. Respir Care 1986;31:271-82.
  16. Comparative physiologic effects of non invasive assist control and pressure support ventilation in acute hypercapnic respiratory failure. Chest 1997;111:1639-49.
  17. Physiologic effects and optimization of nasal assist control ventilation for patients with COPD in respiratory failure. Thorax 1997;52:690-6.
  18. The pattern of breathing during successful and unsuccessful trials of weaning from mechanical ventilation. Am Rev Respir Dis 1986;134:1111-8.
  19. Successful discontinuation of ventilation via tracheostomy by substitution of nasal positive pressure ventilation. Chest 1992;102:1277-9.
  20. Nasal ventilation to facilitate weaning in patients with chronic respiratory insufficiency. Thorax 1992;47:715-8.
  21. Nasal intermittent positive-pressure ventilation in weaning intubated patients with chronic respiratory disease from assisted intermittent, positive pressure ventilation. Respir Med 1993;87:199-204.
  22. Incidence, risk and prognosis factors of Nosocomial pneumonia in mechanically ventilated patients. Am Rev Respir Dis 1990;142:523-8.
  23. Nosocomial pneumonia in ventilated patients: A Cohort study evaluating attributable mortality and hospital stay. Am J Med 1993;94:281-8.
  24. Nosocomial pneumonia in patients receiving continuous mechanical ventilation. Prospective analysis of 52 episodes with use of a protected specimen brush and quantitative culture techniqesd. Am Rev Respir Dis 1989;139:792-6.
  25. Risk factors FPR pneumonia and fatality in patients receiving continuous mechanical ventilation. Am Rev Resp Dis 1986;133:792-6.
  26. Prevention of ventilator-associated pneumonia: Current practice in Canadian intensive care units. J Crit Care 2002;17:161-7.
  27. Pulmonary aspiration of gastric contents in patients receiving mechanical ventilation: The effect of body position. Ann Intern Med 1992;116:540-3.
  28. Semirecumbent position protects from pulmonary aspiration but not completely from gastroesophageal reflux in mechanically ventilated patients. Am J Respir Crit Care Med 1995;152:1387-90.
  29. Gastroesophageal reflux and microaspiration to lower airways in intubated patients: Impact of nasogastric tube size. Ann Intern Med 1999;130:991-4.
  30. Nosocomial Pneumonia: A multivariate analysis of risk and prognosis. Chest 1998;93:318-24.
  31. Noninvasive positive pressure ventilation as a weaning strategy for intubated adults with respiratory failure. Cochrane Database Syst Rev 2003;4:CD004127.
  32. VENISE: Non-invasive ventilation during mechanical ventilation weaning in chronic respiratory failure patients: A prospective randomized controlled and multicentric trial. Rev Mal Respir 2003;20:940-5.
  33. Non-invasive positive pressure ventilation for post-extubation respiratory failure. N Engl J Med 2004;350:2452-60.
PDF Share
PDF Share

© Jaypee Brothers Medical Publishers (P) LTD.