Citation Information :
Inadvertent Vertebral Vein Cannulation: Anatomical Considerations and Practical Aspects. Indian J Crit Care Med 2022; 26 (8):956-957.
A routine vascular procedure, the central venous catheterization requires recognition of malposition to avoid its serious sequelae. This case report discusses the complications encountered following presumed right internal jugular vein cannulation in a trauma patient. Cervical spine imaging done as part of a trauma protocol revealed a catheter in the right vertebral vein. Inadvertently mispositioned catheter emphasizes the significance of ultrasound-guided central vein catheterization even if the cannulation is done using standard anatomical landmarks.
American Association of Clinical Anatomists, Educational Affairs Committee. The clinical anatomy of several invasive procedures. Clin Anat 1999;12(1):43–54. DOI: 10.1002/(SICI)1098-2353(1999)12: 1<43::AID-CA7>3.0.CO;2-W.
Bannon MP, Heller SF, Rivera M. Anatomic considerations for central venous cannulation. Risk Manag Healthc Policy 2011;4:27–39. DOI: 10.2147/RMHP.S10383.
Hind D, Calvert N, McWilliams R, Davidson A, Paisley S, Beverley C, et al. Ultrasonic locating devices for central venous cannulation: meta-analysis. BMJ 2003; 327(7411):361–367. DOI: 10.1136/bmj.327.7411.361.
Karakitsos D, Labropoulos N, De Groot E, Patrianakos AP, Kouraklis G, Poularas J, et al. Real-time ultrasound-guided catheterisation of the internal jugular vein: a prospective comparison with the landmark technique in critical care patients. Crit Care 2006;10(6):R162. DOI: 10.1186/cc5101.
Mehta N, Valesky WW, Guy A, Sinert R. Systematic review: is real-time ultrasonic-guided central line placement by ED physicians more successful than the traditional landmark approach? Emerg Med J 2013;30(5):355–359. DOI: 10.1136/emermed-2012-201230.
Smit JM, Haaksma ME, Lim EHT, Steenvoorden TS, Blans MJ, Bosch FH, et al. Ultrasound to detect central venous catheter placement associated complications: a multicenter diagnostic accuracy study. Anesthesiology 2020;132(4):781–794. DOI: 10.1097/ALN.0000000000003126.
Park SY, Kim MJ, Kim MG, Lee SJ, Kim SH, Ok SY, et al. Changes in the relationship between the right internal jugular vein and an anatomical landmark after head rotation. Korean J Anesthesiol 2011;61:107–111. DOI: 10.4097/kjae.2011.61.2.107.
Lieberman JA, Williams KA, Rosenberg AL. Optimal head rotation for internal jugular vein cannulation when relying on external landmarks. Anesth Analg 2004;99:982–988. DOI: 10.1213/01.ANE.0000132908.77111.CA.