Indian Journal of Critical Care Medicine

Register      Login

SEARCH WITHIN CONTENT

FIND ARTICLE

Volume / Issue

Online First

Archive
Related articles

VOLUME 11 , ISSUE 4 ( October, 2007 ) > List of Articles

ORIGINAL ARTICLE

Determination of intravascular volume status in critically ill patients using portable chest X-rays: Measurement of the vascular pedicle width

Nawal Salahuddin, M. Aslam, Ishtiaq Chishti, Shehla Siddiqui

Keywords : Intravascular volume, critically ill patients, chest X-rays, vascular pedicle

Citation Information : Salahuddin N, Aslam M, Chishti I, Siddiqui S. Determination of intravascular volume status in critically ill patients using portable chest X-rays: Measurement of the vascular pedicle width. Indian J Crit Care Med 2007; 11 (4):192-197.

DOI: 10.4103/0972-5229.37714

License: CC BY-ND 3.0

Published Online: 01-07-2011

Copyright Statement:  Copyright © 2007; The Author(s).


Abstract

Background and Aims: Traditionally, invasive hemodynamic pressure measurements have been used to assess the volume status in critically ill patients. The vascular pedicle, as seen on chest radiographs, is the mediastinal silhouette of the great vessels. It is measured by drawing a perpendicular line from the point at which the left subclavian artery emerges from the aortic arch and measured across to the point at which the superior vena cava crosses the right main stem bronchus. We carried out this study to establish a correlation between the width of the vascular pedicle as seen on chest radiographs and daily fluid balance or pulmonary capillary occlusion pressure in mechanically ventilated, critically ill patients. Materials and Methods: In this prospective clinical study, 50 consecutive adult patients in a tertiary care, multidisciplinary intensive care unit underwent simultaneous measurements of the width of the vascular pedicle as seen on standardized, portable chest radiographs in the supine position and pulmonary capillary occlusion pressure measurements. Twenty-four hour fluid balance calculations were also recorded for each patient. Results: Vascular pedicle width measurements correlated closely with positive fluid balance, r = + 0.88, P 0.000. A Receiver Operating Characteristic curve demonstrated that a vascular pedicle width of 86.5 mm had a 100% sensitivity and an 80% specificity (area under the curve 0.823, 95% confidence intervals 0.714-0.932) for predicting fluid overload equal to and greater than 1200 ml. The correlation between pulmonary capillary occlusion pressures and width of the vascular pedicle was poor, r = 0.41, P 0.02. Conclusions: Our findings suggest that the vascular pedicle width on daily chest radiographs can be used to assess hypervolemia in the intensive care unit. Serial changes in the pedicle width could possibly be used to increase the accuracy of predictions.


PDF Share
  1. Negative fluid balance predicts survival in patients with septic shock: A retrospective pilot study. Chest 2000;117:1749-54.
  2. Rationing critical care beds: A systematic review. Crit Care Med 2004;32:1588-97.
  3. Early goal-directed therapy in the treatment of severe sepsis and septic shock. N Engl J Med 2001;345:1368-77.
  4. The vascular pedicle of the heart and the vena azygos, Part 1: The normal subject. Radiology 1984;152:1-8.
  5. Increased vascular pedicle width preceding burn-related pulmonary edema. Chest 1986;90:649-55.
  6. Appraising pulmonary edema using supine chest roentgenograms in ventilated patients. Am J Respir Crit Care Med 1998;157:1600-8.
  7. Findings on the portable chest radiograph correlate with fluid balance in critically ill patients. Chest 2002;122:2087-95.
  8. Radiologic determination of intravascular volume status using portable, digital chest radiography: A prospective investigation in 100 patients. Crit Care Med 2001;29:1502-12.
  9. Relation between respiratory changes in arterial pulse pressure and fluid responsiveness in septic patients with acute circulatory failure. Am J Respir Crit Care Med 2000;162:134-8.
  10. Systolic pressure variation as a guide to fluid therapy in patients with sepsis-induced hypotension. Anesthesiology 1998;89:1313-21.
  11. The use of transesophageal echocardiography for preload assessment in critically ill patients. Anesth Analg 2000;90:351-5.
  12. Pulmonary artery occlusion pressure and central venous pressure fail to predict ventricular filling volume, cardiac performance or the response to volume infusion in normal subjects. Crit Care Med 2004;32:691-9.
  13. The vascular pedicle of the heart and the vena azygos: Part 2; aquired heart disease. Radiology 1984;152:9-17.
  14. Cardiopulmonary effects of volume expansion in man: Radiographic manifestations. AJR Am J Roentgenol 1985;144:289-93.
  15. Swan-Ganz catheter use and mortality of myocardial infarction patients. Health Care Financ Rev 1994;15:91-103.
  16. Comparison of two fluid-management strategies in acute lung injury. N Engl J Med 2006;354:2564-75.
  17. A multicenter study of physicians′ knowledge of the pulmonary artery catheter. JAMA 1990;264:2928-32.
  18. Improved outcome based on fluid management in critically ill patients requiring pulmonary artery catheterization. Am Rev Respir Dis 1992;145:990-8.
  19. Meta-analysis of haemodynamic optimization in high-risk patients. Crit Care Med 2002;30:1686-92.
  20. Tissue Doppler imaging estimation of pulmonary artery occlusion pressure in ICU patients. Intensive Care Med 2004;30:75-81.
  21. Noninvasive estimation of right atrial pressure from the inspiratory collapse of the inferior vena cava. Am J Cardiol 1990;66:493-6.
  22. Haemodynamic instability in sepsis: Bedside assessment by Doppler echocardiography. Am J Respir Crit Care Med 2003;168:1270-6.
  23. Respiratory changes in aortic blood flow velocity as an indicator of fluid responsiveness in ventilated patients with septic shock. Chest 2001;119:867-73.
  24. Respiratory changes in IVC diameter are helpful in predicting fluid responsiveness in ventilated septic patients. Intensive Care Med 2004;30:1740-6.
  25. Assessing fluid responsiveness by stroke volume variation in mechanically ventilated patients with severe sepsis. Eur J Anaesthesiol 2004;21:132-8.
  26. Reliability of a new algorithm for continuous cardiac output determination by pulse-contour analysis during haemodynamic instability. Crit Care Med 2002;30:52-8.
  27. The impact of routine chest radiography on ICU management decisions: An observational study. Am J Crit Care 1997;6:95-8.
  28. Body fluid volume status in heamodialysis patients: The value of the chest radiograph. Can Assoc Radiol J 1990;41:123-6.
PDF Share
PDF Share

© Jaypee Brothers Medical Publishers (P) LTD.