Agreement between inferior vena cava diameter measurements by subxiphoid versus transhepatic views

Jigeeshu V. Divatia, Harish Chaudhari, S. Janarthanan, Harish M. M, Siddique Suhail, Vijaya P. Patil

Keywords : Fluid responsiveness, inferior vena cava collapsibility, inferior vena cava diameter, inferior vena cava distensibility, limits of agreement

Citation Information : Divatia JV, Chaudhari H, Janarthanan S, M HM, Suhail S, Patil VP. Agreement between inferior vena cava diameter measurements by subxiphoid versus transhepatic views. Indian J Crit Care Med 2015; 19 (12):719-722.

DOI: 10.4103/0972-5229.171390

License: CC BY-ND 3.0

Published Online: 01-04-2013

Copyright Statement:  Copyright © 2015; The Author(s).


Abstract

Context: Correcting hypovolemia is extremely important. Central venous pressure measurement is often done to assess volume status. Measurement of inferior vena cava (IVC) is conventionally done in the subcostal view using ultrasonography. It may not be possible to obtain this view in all patients. Aims: We therefore evaluated the limits of agreement between the IVC diameter measurement and variation in subcostal and that by the lateral transhepatic view. Settings and Design: Prospective study in a tertiary care referral hospital intensive care unit. Subjects and Methods: After Institutional Ethics Committee approval and informed consent, we obtained 175 paired measurements of the IVC diameter and variation in both the views in adult mechanically ventilated patients. The measurements were carried out by experienced researchers. We then obtained the limits of agreement for minimum, maximum diameter, percentage variation of IVC in relation to respiration. Statistical Analysis Used: Bland-Altman′s limits of agreement to get precision and bias. Results: The limits of agreement were wide for minimum and maximum IVC diameter with variation of as much as 4 mm in both directions. However, the limits of agreement were much narrower when the percentage variation in relation to respiration was plotted on the Bland-Altman plot. Conclusions: We conclude that when it is not possible to obtain the subcostal view, it is possible to use the lateral transhepatic view. However, using the percentage variation in IVC size is likely to be more reliable than the absolute diameter alone. It is possible to use both views interchangeably.


PDF Share
  1. Boyd JH, Forbes J, Nakada TA, Walley KR, Russell JA. Fluid resuscitation in septic shock: A positive fluid balance and elevated central venous pressure are associated with increased mortality. Crit Care Med 2011;39:259-65.
  2. Vincent JL, Sakr Y, Sprung CL, Ranieri VM, Reinhart K, Gerlach H, et al. Sepsis in European intensive care units: Results of the SOAP study. Crit Care Med 2006;34:344-53.
  3. Kitakule MM, Mayo P. Use of ultrasound to assess fluid responsiveness in the intensive care unit. Open Crit Care Med J 2010;3:33-7.
  4. American College of Emergency Physicians. American College of Emergency Physicians. ACEP emergency ultrasound guidelines-2001. Ann Emerg Med 2001;38:470-81.
  5. Barbier C, Loubières Y, Schmit C, Hayon J, Ricôme JL, Jardin F, et al. Respiratory changes in inferior vena cava diameter are helpful in predicting fluid responsiveness in ventilated septic patients. Intensive Care Med 2004;30:1740-6.
  6. Feissel M, Michard F, Faller JP, Teboul JL. The respiratory variation in inferior vena cava diameter as a guide to fluid therapy. Intensive Care Med 2004;30:1834-7.
  7. Zengin S, Al B, Genc S, Yildirim C, Ercan S, Dogan M, et al. Role of inferior vena cava and right ventricular diameter in assessment of volume status: A comparative study: Ultrasound and hypovolemia. Am J Emerg Med 2013;31:763-7.
  8. Moreno FL, Hagan AD, Holmen JR, Pryor TA, Strickland RD, Castle CH. Evaluation of size and dynamics of the inferior vena cava as an index of right-sided cardiac function. Am J Cardiol 1984;53:579-85.
  9. Nette RW, Ie EH, Vletter WB, Krams R, Weimar W, Zietse R. Norepinephrine-induced vasoconstriction results in decreased blood volume in dialysis patients. Nephrol Dial Transplant 2006;21:1305-11.
  10. Mandelbaum A, Ritz E. Vena cava diameter measurement for estimation of dry weight in haemodialysis patients. Nephrol Dial Transplant 1996;11 Suppl 2:24-7.
  11. Dipti A, Soucy Z, Surana A, Chandra S. Role of inferior vena cava diameter in assessment of volume status: A meta-analysis. Am J Emerg Med 2012;30:1414-1419.e1.
  12. Yanagawa Y, Nishi K, Sakamoto T, Okada Y. Early diagnosis of hypovolemic shock by sonographic measurement of inferior vena cava in trauma patients. J Trauma 2005;58:825-9.
  13. Sefidbakht S, Assadsangabi R, Abbasi HR, Nabavizadeh A. Sonographic measurement of the inferior vena cava as a predictor of shock in trauma patients. Emerg Radiol 2007;14:181-5.
  14. Akilli B, Bayir A, Kara F, Ak A, Cander B. Inferior vena cava diameter as a marker of early hemorrhagic shock: A comparative study. Ulus Travma Acil Cerrahi Derg 2010;16:113-8.
  15. Schefold JC, Storm C, Bercker S, Pschowski R, Oppert M, Krüger A, et al. Inferior vena cava diameter correlates with invasive hemodynamic measures in mechanically ventilated intensive care unit patients with sepsis. J Emerg Med 2010;38:632-7.
  16. Fields JM, Lee PA, Jenq KY, Mark DG, Panebianco NL, Dean AJ. The interrater reliability of inferior vena cava ultrasound by bedside clinician sonographers in emergency department patients. Acad Emerg Med 2011;18:98-101.
  17. Akkaya A, Yesilaras M, Aksay E, Sever M, Atilla OD. The interrater reliability of ultrasound imaging of the inferior vena cava performed by emergency residents. Am J Emerg Med 2013;31:1509-11.