Correlation between Transcranial Ultrasound and CT Head to Detect Clinically Significant Conditions in Post-craniectomy Patients Performed by Emergency Physician: A Pilot Study
Rahul Chouhan, Tej P Sinha, Sanjeev Bhoi, Atin Kumar, Deepak Agrawal, Jamshed Nayer, Ravindra M Pandey, Praveen Aggarwal, Meera Ekka, Prakash R Mishra, Akshay Kumar, Divya C Chouhan
Keywords :
Decompressive craniectomy, Point of care ultrasound, Transcranial ultrasound
Citation Information :
Chouhan R, Sinha TP, Bhoi S, Kumar A, Agrawal D, Nayer J, Pandey RM, Aggarwal P, Ekka M, Mishra PR, Kumar A, Chouhan DC. Correlation between Transcranial Ultrasound and CT Head to Detect Clinically Significant Conditions in Post-craniectomy Patients Performed by Emergency Physician: A Pilot Study. Indian J Crit Care Med 2024; 28 (3):299-306.
Background: The main objective is to detect clinically significant conditions by transcranial ultrasound (TCS) in post-decompressive craniectomy (DC) patients who come to the emergency department. Materials and methods: This was a cross-sectional observational study. We studied 40 post-DC patients. After primary stabilization, TCS was done. Computer tomography of head was done within 2 hours of performing TCS. The correlation between both modalities were assessed by the measurement of lateral ventricle (LV) (Bland-Altman plot), Midline shift and mass lesion. Additionally, normal cerebral anatomy, 3rd and 4th ventricles and external ventricular drainage (EVD) catheter visualization were also done. Results: About 14/40 patients came with non-neurosurgical complaints and 26/40 patients came with neurosurgical complaints. Patients with non-neurosurgical complaints (4/14) had mass lesions and 1/14 had MLS. Patients with neurosurgical complaints (11/26) had mass lesions and about 5 patients had MLS. A good correlation was found between TCS and CT of head in measuring LV right (CT head = 17.4 ± 13.8 mm and TCS = 17.1 ± 14.8 mm. The mean difference (95% CI) = [0.28 (–1.9 to 1.33), ICC 0.93 (0.88–0.96)], Left [CT head = 17.8 ± 14.4 mm and TCS = 17.1 ± 14.2 mm, the mean difference (95% CI) 0.63 (–1.8 to 0.61), ICC 0.96 (0.93–0.98)], MLS [CT head = 6.16 ± 3.59 (n = 7) and TCS = 7.883 ± 4.17 (n = 6)] and mass lesions (kappa 0.84 [0.72–0.89] [95% CI] p-value < 0.001). The agreement between both modalities for detecting mass lesions is 93.75%. Conclusion: Point of care ultrasound (POCUS) is a bedside, easily operable, non-radiation hazard and dynamic imaging tool that can be used for TCS as a supplement to CT head in post-DC patients in emergency as well as in ICU. However, assessment of the ventricular system (pre/post-EVD insertion), monitoring of regression/progression of mass lesion, etc. can be done with TCS. Repeated scans are possible in less time which can decrease the frequency of CT head.
Schirmer CM, Ackil AA Jr, Malek AM. Decompressive craniectomy. Neurocrit Care 2008;8(3):456–470. DOI: 10.1007/s12028-008-9082-y.
Gopalakrishnan MS, Shanbhag NC, Shukla DP, Konar SK, Bhat DI, Devi BI. Complications of decompressive craniectomy. Front Neurol 2018;9:977. DOI: 10.3389/fneur.2018.00977.
Ban SP, Son YJ, Yang HJ, Chung YS, Lee SH, Han DH. Analysis of complications following decompressive craniectomy for traumatic brain injury. J Korean Neurosurg Soc 2010;48(3):244–250. DOI: 10.3340/jkns.2010.48.3.244.
Fernando SM, Tran A, Cheng W, Rochwerg B, Taljaard M, Kyeremanteng K, et al. Diagnosis of elevated intracranial pressure in critically ill adults: Systematic review and meta-analysis BMJ 2019;366:l4225. DOI: 10.1136/bmj.l4225.
Ultrasound Guidelines: Emergency, point-of-care and clinical ultrasound guidelines in medicine. Ann Emerg Med 2017;69(5): e27–e54. DOI: 10.1016/j.annemergmed.2016.08.457.
Brunda RL, Keri VC, Sinha TP, Bhoi S, Mishra PR. ‘Sono-cardiopulmonary resuscitation’ in COVID-19: A proposed algorithm. Postgrad Med J 2021;97(1143):3–4. DOI: 10.1136/postgradmedj-2020-138747.
Shrimal P, Bhoi S, Sinha TP, Murmu LR, Nayer J, Ekka M, et al. Sensitivity and specificity of waterbath ultrasound technique in comparison to the conventional methods in diagnosing extremity fractures. Am J Emerg Med 2022;53:118–121. DOI: 10.1016/j.ajem.2021.12.067.
Vishnu VK Bhoi S, Aggarwal P, Murmu LR, Agrawal D, Kumar A, Sinha TP, et al. Diagnostic utility of point of care ultrasound in identifying cervical spine injury in emergency settings. Australas J Ultrasound Med 2021;24(4):208–216. DOI: 10.1002/ajum.12274.
Fred HL. Drawbacks and limitations of computed tomography. Tex Heart Inst J 2004;31(4):4. PMID: 16107131.
Gupta P, Sodhi KS, Saxena AK, Khandelwal N, Singhi P. Neonatal cranial sonography: A concise review for clinicians. J Pediatr Neurosci 2016;11(1):7–13. DOI: 10.4103/1817-1745.181261.
Najjar A, Denault AY, Bojanowski MW. Bedside transcranial sonography monitoring in a patient with hydrocephalus post subarachnoid hemorrhage. Crit Ultrasound J 2017;9(1):17. DOI: 10.1186/s13089-017-0072-1.
Hoskins PR, Martin K, Thrush A, editors. The British Medical Ultrasound Society. Guidelines for the safe use of diagnostic ultrasound equipment. In: Diagnostic Ultrasound [Internet]. 2nd ed. Cambridge: Cambridge University Press; 2010 [cited 2021 Dec 5]. pp. 217–225.
Caricato A, Mignani V, Bocci MG, Pennisi MA, Sandroni C, Tersali A, et al. Usefulness of transcranial echography in patients with decompressive craniectomy: A comparison with computed tomography scan. Crit Care Med 2012;40(6):1745–1752. DOI: 10.1097/CCM.0b013e318246b6ea.
Bendella H, Maegele M, Hartmann A, Spreer J, Rommel N, Lefering R, et al. Cerebral ventricular dimensions after decompressive craniectomy: A comparison between bedside sonographic duplex technique and cranial computed tomography. Neurocrit Care 2017;26(3): 321–329. DOI: 10.1007/s12028-016-0359-2.
Kobayashi S, Kitamura T, Isayama K, Yokota H, Nakazawa S. Clinical value of bedside ultrasonography in craniectomized patients. Neurol Med Chir (Tokyo) 1989;29(8):740–745. Japanese. DOI: 10.2176/nmc.29.740.
Olislagers-De Slegte RG, Smeets RW, Valk J, Crezée F. Ultrasound in follow-up of the postoperative brain. Preliminary report on six cases. Neuroradiology 1984;26(4):267–272. DOI: 10.1007/BF00339769.
de Siegte RGM, Valk J, Broere G, de Waal F. Further experience with ultrasound examinations in the postoperative brain. Acta Neurochir 1986;81(3–4):106–112. DOI: 10.1007/BF01401230.
Martín F, Ochoa J. Ecografía transcraniectomía. Revista Argentina de Radiología 2015;79(4):205–208. DOI: 10.1016/j.rard.2015.03.003.
Al Sawaf A, Arya K, Murr N. Seizure Precautions. [Updated 2021 Sep 2]. In: StatPearls [Internet]. Treasure Island (FL): StatPearls Publishing; 2021.
Skalski M, Yonso M. Acoustic shadowing. Reference article, Radiopaedia.org. DOI: https://doi.org/10.53347/rID-24967. Accessed on: 10 Dec 2021.
Srinivasan S, Kumar PG, Govil D, Gupta S, Kumar V, Pichamuthu K, et al. Competencies for point-of-care ultrasonography in ICU: An ISCCM Expert Panel Practice Recommendation. Indian J Crit Care Med 2022;26(Suppl 2):S7–S12. DOI: 10.5005/jp-journals-10071-24199.
Kapoor I, Pandit S, Prabhakar H, Mahajan C. Comparison between transcranial sonography and computerized tomography scans to assess the midline shift in patients with traumatic brain injury. Indian J Crit Care Med 2023;27(1):64–66. DOI: 10.5005/jp-journals- 10071-24376.
Morgan M, Bell D. Reverberation artifact. Reference article, Radiopaedia.org. DOI: https://doi.org/10.53347/rID-31989. Accessed on: 10 Dec 2021.