Cracking the Code of AKI: Evaluating the Predictive Power of VExUS Scoring in Critically Ill Noncardiac Patients
Waseem Ahmad Khan, Vikas Saini, Alisha Goel, Anas Valiyaparambath
Keywords :
2D Echocardiography, Acute kidney injury, Critical care, Intensive care unit, Mortality, Learning ultrasound in critical care
Citation Information :
Khan WA, Saini V, Goel A, Valiyaparambath A. Cracking the Code of AKI: Evaluating the Predictive Power of VExUS Scoring in Critically Ill Noncardiac Patients. Indian J Crit Care Med 2025; 29 (3):236-243.
Background: Numerous signs of venous congestion exist, but each has limitations. Previous studies have shown the utility of venous excess ultrasound (VExUS) scoring in predicting acute kidney injury (AKI) in patients postcardiac surgery. This study aimed to evaluate whether serial VExUS scoring could predict AKI in intensive care unit (ICU) patients without cardiac conditions.
Materials and methods: This single-center observational study was conducted in the main ICU of PGIMER, Chandigarh, India. Thirty patients with an inferior vena cava (IVC) diameter of ≥2 cm and a normal biventricular function were included. Serial VExUS scoring was performed on admission and daily for up to six days or until AKI developed, whichever occurred first.
Results: Among 30 participants, 22 (73.3%) developed AKI. In the AKI group, mean VExUS scores were 1.95 on day 2, 1.92 on day 3, and 3.0 on day 5 (p = 0.001, 0.003, and 0.002, respectively). A significant positive correlation was observed between VExUS scores and fluid balance on day 2 (ρ = 0.375, p = 0.041) and day 3 (ρ = 0.579, p = 0.006). Multivariate analysis showed no correlation between the VExUS score on day 2 and fluid balance, duration of mechanical ventilation, or ICU length of stay. No association was found between VExUS scores and 30-day mortality.
Conclusion: In critically ill noncardiac patients, VExUS scores do not predict AKI onset. However, higher daily fluid balance may moderately correlate with VExUS scores.
O’Connor ME, Prowle JR. Fluid overload. Crit Care Clin 2015;31(4):803–821. DOI: 10.1016/j.ccc.2015.06.013.
Salahuddin N, Sammani M, Hamdan A, Joseph M, Al-Nemary Y, Alquaiz R, et al. Fluid overload is an independent risk factor for acute kidney injury in critically ill patients: Results of a cohort study. BMC Nephrol 2017;18(1):45. DOI: 10.1186/s12882-017-0460-6.
Messmer AS, Zingg C, Müller M, Gerber JL, Schefold JC, Pfortmueller CA. Fluid overload and mortality in adult critical care patients: A systematic review and meta-analysis of observational studies. Crit Care Med 2020;48(12):1862–1870. DOI: 10.1097/CCM.0000000000004624.
Lichtenstein D. Lung ultrasound in the critically ill. Curr Opin Crit Care 2014;20(3):315–322. DOI: 10.1097/MCC.0000000000000096.
Alexandrou M-E, Theodorakopoulou MP, Sarafidis PA. Lung ultrasound as tool to evaluate fluid accumulation in dialysis patients. Kidney Blood Press Res 2022;47(1):164–178. DOI: 10.1159/000521199.
Feissel M, Michard F, Faller JP, Teboul JL. The respiratory variation in inferior vena cava diameter as a guide to fluid therapy. Intensive Care Med 2004;30(9):1834–1837. DOI: 10.1007/s00134-004-2233-5.
Orso D, Paoli I, Piani T, Cilenti FL, Cristiani L, Guglielmo N. Accuracy of ultrasonographic measurements of inferior vena cava to determine fluid responsiveness: A systematic review and meta-analysis. J Intensive Care Med 2020;35(4):354–363. DOI: 10.1177/0885066618762743.
Beaubien-Souligny W, Benkreira A, Robillard P, Bouabdallaoui N, Chassé M, Desjardins G, et al. Alterations in portal vein flow and intrarenal venous flow are associated with acute kidney injury after cardiac surgery: A prospective observational cohort study. J Am Heart Assoc 2018;7(19)\:e009961. DOI: 10.1161/JAHA.118.009961.
Bhardwaj V, Vikneswaran G, Rola P, Raju S, Bhat RS, Jayakumar A, et al. Combination of inferior vena cava diameter, hepatic venous flow, and portal vein pulsatility index: Venous excess ultrasound score in predicting acute kidney injury in patients with cardiorenal syndrome: A prospective cohort study. Indian J Crit Care Med 2020;24(9):783–789. DOI: 10.5005/jp-journals-10071-23566.
Andrei S, Bahr PA, Nguyen M, Bouhemad B, Guinot PG. Prevalence of systemic venous congestion assessed by the venous excess ultrasound grading system and association with acute kidney injury in a general ICU cohort: A prospective multicentric study. Crit Care 2023;27(1):224. DOI: 10.1186/s13054-023-04524-4.
Beaubien-Souligny W, Rola P, Haycock K, Bouchard J, Lamarche Y, Spiegel R, et al. Quantifying systemic congestion with point-of-care ultrasound: Development of the venous excess ultrasound grading system. Ultrasound J 2020;12(1):1–12. DOI: 10.1186/s13089-020-00163-w.
Huette P, Guinot PG, Haye G, Moussa MD, Beyls C, Guilbart E, et al. Portal vein pulsatility as a dynamic marker of venous congestion following cardiac surgery: An interventional study using positive end-expiratory pressure. J Clin Med 2021;10(24):5921. DOI: 10.3390/jcm10245921.
Spiegel R, Teeter W, Sullivan S, Tupchong K, Mohammed N, Sutherland M, et al. The use of venous Doppler to predict adverse kidney events in a general ICU cohort. Crit Care 2020;24(1):615. DOI: 10.1186/s13054-020-03330-6.
Kumar V. VeXUS: Do Not Drown in the ExCESS. Indian J Crit Care Med 2024;28(5):419–421. DOI: 10.5005/jp-journals-10071-24711.
Malbrain ML, Marik PE, Witters I, Cordemans C, Kirkpatrick AW, Roberts DJ, et al. Fluid overload, de-resuscitation, and outcomes in critically ill or injured patients: A systematic review with suggestions for clinical practice. Anaesthesiol Intensive Ther 2014;46(5):361–380. DOI: 10.5603/AIT.2014.0060.
Meyhoff TS, Møller MH, Hjortrup PB, Cronhjort M, Perner A, Wetterslev J. Lower vs higher fluid volumes during initial management of sepsis: A systematic review with meta-analysis and trial sequential analysis. Chest 2020;157(6):1478–1496. DOI: 10.1016/j.chest.2019.12.012.